Gigabyte Aorus Xtreme TRX40: Difference between revisions
No edit summary |
No edit summary |
||
| (4 intermediate revisions by the same user not shown) | |||
| Line 4: | Line 4: | ||
There is both a ITE IT8688E for 6 temperature readings and 5 fans, and an ITE IT879XE for 3 more of each. Seven of the sensors are built into the motherboard, and two use external thermistors. The in-kernel driver will not recognize the 8688. Employ <tt>force_id=0x8688</tt>. | There is both a ITE IT8688E for 6 temperature readings and 5 fans, and an ITE IT879XE for 3 more of each. Seven of the sensors are built into the motherboard, and two use external thermistors. The in-kernel driver will not recognize the 8688. Employ <tt>force_id=0x8688</tt>. | ||
== | {| class="wikitable" style="display: inline-table;" | ||
|+ it8688-isa-0a60 | |||
|- | |||
! sensors !! UEFI | ! sensors !! UEFI | ||
|- | |- | ||
| Line 14: | Line 15: | ||
| fan3 || <tt>FAN_SYS2</tt> | | fan3 || <tt>FAN_SYS2</tt> | ||
|- | |- | ||
| fan4 || | | fan4 || <tt>PCH_FAN</tt> | ||
|- | |- | ||
| fan5 || | | fan5 || <tt>CPU_OPT</tt> | ||
|- | |- | ||
| temp1 || | | temp1 || SYS1 | ||
|- | |- | ||
| temp2 || | | temp2 || VRMMOS | ||
|- | |- | ||
| temp3 || | | temp3 || PCH | ||
|- | |- | ||
| temp4 || | | temp4 || SYS2 | ||
|- | |- | ||
| temp5 || | | temp5 || CPU | ||
|- | |- | ||
| temp6 || | | temp6 || EC1 | ||
|- | |- | ||
|} | |} | ||
{| class="wikitable" style="display: inline-table;" | |||
|+ it8688-isa-0a60 | |||
|- | |||
! sensors !! UEFI | ! sensors !! UEFI | ||
|- | |- | ||
| fan1 || | | fan1 || <tt>FAN_PUMP5A</tt> | ||
|- | |- | ||
| | | fan2 || <tt>FAN_PUMP6</tt> | ||
|- | |- | ||
| | | fan3 || <tt>FAN_SYS4</tt> | ||
|- | |- | ||
| temp1 || | | temp1 || PCIE_X162 | ||
|- | |- | ||
| temp2 || | | temp2 || EC2 | ||
|- | |- | ||
| temp3 || | | temp3 || PCIE_X161 | ||
|- | |- | ||
|} | |} | ||