Line 4: Line 4:
There is both a ITE IT8688E for 6 temperature readings and 5 fans, and an ITE IT879XE for 3 more of each. Seven of the sensors are built into the motherboard, and two use external thermistors. The in-kernel driver will not recognize the 8688. Employ <tt>force_id=0x8688</tt>.
There is both a ITE IT8688E for 6 temperature readings and 5 fans, and an ITE IT879XE for 3 more of each. Seven of the sensors are built into the motherboard, and two use external thermistors. The in-kernel driver will not recognize the 8688. Employ <tt>force_id=0x8688</tt>.


===it8688-isa-0a40===
{| class="wikitable" style="display: inline-table;"
{| class="wikitable"
|+ it8688-isa-0a60
|-
! sensors !! UEFI
! sensors !! UEFI
|-
|-
Line 14: Line 15:
| fan3 || <tt>FAN_SYS2</tt>
| fan3 || <tt>FAN_SYS2</tt>
|-
|-
| fan4 ||
| fan4 || <tt>PCH_FAN</tt>
|-
|-
| fan5 ||
| fan5 || <tt>CPU_OPT</tt>
|-
|-
| temp1 ||
| temp1 || SYS1
|-
|-
| temp2 ||
| temp2 || VRMMOS
|-
|-
| temp3 ||
| temp3 || PCH
|-
|-
| temp4 ||
| temp4 || SYS2
|-
|-
| temp5 ||
| temp5 || CPU
|-
|-
| temp6 ||
| temp6 || EC1
|-
|-
|}
|}
 
{| class="wikitable" style="display: inline-table;"
===it8688-isa-0a60===
|+ it8688-isa-0a60
{| class="wikitable"
|-
! sensors !! UEFI
! sensors !! UEFI
|-
|-
| fan1 ||
| fan1 || <tt>FAN_PUMP5A</tt>
|-
| fan2 ||
|-
| fan3 ||
|-
|-
| fan4 ||
| fan2 || <tt>FAN_PUMP6</tt>
|-
|-
| fan5 ||
| fan3 || <tt>FAN_SYS4</tt>
|-
|-
| temp1 ||
| temp1 || PCIE_X162
|-
|-
| temp2 ||
| temp2 || EC2
|-
|-
| temp3 ||
| temp3 || PCIE_X161
|-
|-
|}
|}