* Sensors are notoriously inaccurate. You can explore their relative systematic inaccuracy by placing them immediately after one another in series (this can of course be changed later). Sensors like to be level relative to gravity. | * Sensors are notoriously inaccurate. You can explore their relative systematic inaccuracy by placing them immediately after one another in series (this can of course be changed later). Sensors like to be level relative to gravity. | ||
* Quality radiators will generally be designed such that the screw holes don't sit atop any water-carrying channels, or that a plate sits between the screw holes and any such channels. It is otherwise possible, however, that screwing in too far will pierce a channel. Use screws of the proper length for your radiator and whatever you're binding to it. | |||
* '''Your loop is never a vacuum'''. This is good, as nature would otherwise abhor it. Assuming you're not actively asphixiating, you're working in at atmosphere of air, and air fills the regions of your loop not filled by water. In particular, when you've first hooked everything up and before you've begun to fill the loop with water, your loop is filled with the equal volume of air. Water cannot exist where air already does, and thus air must leave your system for water to enter. There are three ways to accomplish this: | |||
** Use a powerful vacuum pump to evacuate the system. Contact your local HVAC technician to explore this route. | |||
** Ensure air can leave from the same place you're adding coolant. This can be accomplished via filling with a graduated cylinder, a filling bottle, or anything else with less area than the inlet, and ought eliminate any air below the inlet. Noticeably, a funnel attached to a fitting, screwed into the inlet, will generally block the entire area and not allow air to leave. | |||
** Ensure air can leave from somewhere else, some outlet. This ought eliminate any air below the outlet. Once coolant reaches the level of the outlet (or the inlet), further filling will eliminate coolant, rather than air. This is also known as "making a mess", and is undesirable. | |||
It is hopefully obvious from this that your filling inlet ought be as high in the loop as possible, and essentially must be in order to quickly remove air. This ought be considered when designing your loop. If it's impossible to get it there, rotate your case while filling. | |||
* It is natural that pockets of air will persist in your system after filling it. Microbubbles will eventually diffuse naturally out of the system, but larger bubbles need your help. Air, being lighter than water, naturally moves to the local top of a section of the loop. It is thus advisable that your reservoir (and filling point) be as high in the loop as possible. Rotate the machine while the pump is running, attempting to coax the bubble to your reservoir (or any point where you can allow air to leave). |
Revision as of 07:33, 2 May 2022
I got some good feedback regarding my earlier "reflections on watercooling" piece, and I thought of a few things I'd missed, so here's some more dankwisdom. Take it for whatever it's worth. Please feel encouraged to send in further data for these tables, assuming you got the info directly from the manufacturer, or rigorously acquired it yourself (don't send me data you read off some web forum).
- Tubing (soft tubing anyway—if you'll recall, I have never used hard tubing, and don't intend to) exists in your loop for three reasons:
- it is cheaper per unit length than metallic fittings,
- it can be cut to arbitrary lengths, and
- it is flexible.
Don't be tempted to directly connect components with metallic fittings. Unlike soft tubing, fittings are completely rigid, not admitting even sub-millimeter deviations. You're effectively working with hard tubing at this point. You might manage to get things hooked up, but check the base of your connections: you'l likely find that the last threads are poorly seated. This is a recipe for slow leaks. This means components must be, at a minimum, two compression fittings' lengths apart.
- Some general tips regarding soft tubing:
- Check your compression fittings' o-rings for dirt, washing them if necessary. Damaged o-rings must be replaced. Without functioning o-rings, the fitting may not be waterproof.
- Cut generously, then trim as necessary. You can't add length back to your tubing.
- With compression fittings, I recommend first completing a compression mating on one end of the tube, then screwing this complete mating into the source, then screwing a fitting base into the target, then performing a cut, then putting the fitting ring onto the end of the tube, then putting the tube onto the (fixed) fitting base, then finally tightening the fitting ring. Don't try to complete both compression matings outside of the loop; screwing in one side will unscrew the other side, and if you attempt to hold the other side, it'll twist the tube.
- If you're having difficulty getting the fitting ring onto the tube, run some warm water over the tube's end. It'll get in there eventually.
- To tighten the fitting ring onto a fitting base in the last step, use your secondary hand to hold the tube fixed (it ought not move during the process), and your primary hand to rotate the fitting to the right while pushing it constantly towards the base.
- Knowing the volume of your components is useful for working the heat equations, for knowing how much coolant you'll need (particularly relevant when using concentrates), and also for determining completion when filling or draining. Unfortunately, this information isn't generally published. I've measured some components using a graduated cylinder at 22℃. The cylinder was labeled at 2mL increments, so no more than 2mL of precision can be assumed. This is unfortunate, as most fittings hold not much more than that. I would measure them with a more accurate pipette, except that it really doesn't matter; their volumes will be dwarfed by your reservoirs/radiators, and probably even by your tubing.
Component | Volume (mL) |
---|---|
Hardware Labs XFLOW 240 radiator | 90 |
Hardware Labs GTR 360 radiator | 320 |
Hardware Labs GTS 360 radiator | 130 |
EKWB Aorus Master monoblock | 45 |
EKWB EK-Vector waterblock | 50 |
EKWB Quantum Kinetic FLT 240 reservoir+pump | 265 |
DiyHZ sensor | 4 |
Monsoon Series Two reseroir+pump | 300 |
EKWB XTOP Dual D5 pump | 35 |
aquacomputer highflow NEXT sensor | 8 |
EKWB Quantum Torque 45° rotary adapter | 2 |
For those of you who dropped out before the first grade, the volume of your (cylindrical) tubing can be calculated by multiplying the length of the tubing by pi by half the inner diameter squared. Area of a circle is πr², r is a radius (half of your inner diameter), and the volume is then area times length. If it's not obvious, this works no matter how you might curve or bend your tube.
Compression fittings negligibly effect the total volume. If you wanted to model their impact, each tube ought be considered shorter by twice the length of the barb (the extrusion inserted into your tube), indicating the volume occupied by the barb. The barb's volume in this region is then equal to that length times, once again, the area of the barb's interior. Using calipers, I measured the inner diameters of some compression fittings intended for 0.5in (12.7mm) inner diameter tubing:
Barb model | Inner diameter (mm) | Length (mm) | Volume (mL) | Δ (mL) |
---|---|---|---|---|
EKWB EK-AH | 10.9 | 10.0 | 0.933 | 0.334 |
EKWB Quantum Torque | 8.75 | 10.0 | 0.601 | 0.666 |
The non-linearity of the r² term is obvious here: the Quantum Torque inner diameter is 80.3% of the EK-AH's, but the total volume is only 64.4%. Either way, 10mm of the tubing is 1.267mL, so you're talking ¾ or ½ of that in the fitting. Assuming half-inch tubing, you can thus subtract 0.666mL for every Quantum Torque compression fitting, or 0.334 for every EK-AH. A 200mL reservoir would represent almost 600 times this latter value. You can use this same reasoning to calculate the (very small) volume loss at each fitting juncture—just use the inner diameter of the threading.
- When completely idled, a modern processor ought be using only a handful of watts. This is insubstantial heating at the surface area of an integrated heat spreader / waterblock. Ergo, an idled processor ought report temperatures roughly equal to the coolant's temperature. If an idle processor reports temperatures more than a degree or two over the coolant's temperature (modulo any systematic error in your sensors), you have most likely fucked up application of the thermal paste. If they don't, you most likely haven't; congratulations.
- Sensors are notoriously inaccurate. You can explore their relative systematic inaccuracy by placing them immediately after one another in series (this can of course be changed later). Sensors like to be level relative to gravity.
- Quality radiators will generally be designed such that the screw holes don't sit atop any water-carrying channels, or that a plate sits between the screw holes and any such channels. It is otherwise possible, however, that screwing in too far will pierce a channel. Use screws of the proper length for your radiator and whatever you're binding to it.
- Your loop is never a vacuum. This is good, as nature would otherwise abhor it. Assuming you're not actively asphixiating, you're working in at atmosphere of air, and air fills the regions of your loop not filled by water. In particular, when you've first hooked everything up and before you've begun to fill the loop with water, your loop is filled with the equal volume of air. Water cannot exist where air already does, and thus air must leave your system for water to enter. There are three ways to accomplish this:
- Use a powerful vacuum pump to evacuate the system. Contact your local HVAC technician to explore this route.
- Ensure air can leave from the same place you're adding coolant. This can be accomplished via filling with a graduated cylinder, a filling bottle, or anything else with less area than the inlet, and ought eliminate any air below the inlet. Noticeably, a funnel attached to a fitting, screwed into the inlet, will generally block the entire area and not allow air to leave.
- Ensure air can leave from somewhere else, some outlet. This ought eliminate any air below the outlet. Once coolant reaches the level of the outlet (or the inlet), further filling will eliminate coolant, rather than air. This is also known as "making a mess", and is undesirable.
It is hopefully obvious from this that your filling inlet ought be as high in the loop as possible, and essentially must be in order to quickly remove air. This ought be considered when designing your loop. If it's impossible to get it there, rotate your case while filling.
- It is natural that pockets of air will persist in your system after filling it. Microbubbles will eventually diffuse naturally out of the system, but larger bubbles need your help. Air, being lighter than water, naturally moves to the local top of a section of the loop. It is thus advisable that your reservoir (and filling point) be as high in the loop as possible. Rotate the machine while the pump is running, attempting to coax the bubble to your reservoir (or any point where you can allow air to leave).